How to Submit a Claim to SCE

If you have suffered a loss or damage due to recent service interruption, and believe we may be responsible, you may submit a claim. How to submit your claim >

We investigate and evaluate each claim individually, and our policy is to respond promptly.

Power Restored to Long Beach Customers

Power has been restored to all customers in Long Beach and they are now reconnected to the electrical network. Generators that had been serving those remaining customers have been disconnected. Our crews will remain working in Long Beach and we will continue to closely monitor network operations.

We thank you for your patience. We encourage customers in Long Beach to make every effort to conserve use of electricity as we continue to return the system to its full operational capacity. The safety of the public and our crews remain our highest priority.

We thank the city of Long Beach for its cooperation and for the especially important safety efforts of first responders in the Long Beach Fire and Police departments. Get the latest update >

Regulatory Information - SCE Load Profiles

2010 Static Load Profiles

The data files in this section are static load profiles for 2010. Each file is a rate group annual profile developed using a three-year average of historical rate group load profiles. These load profiles are based on the 2005-2007 class average load profiles for 11 separate groups. Refer to the methodology of creating static load profiles for a description of the estimation process.

On May 18, 1998, SCE began implementing dynamic load profiles in place of static profiles for residential (Domestic Single/Multiple), Small Commercial (GS-1), and medium commercial/industrial (GS-2) customers. As of that date, only dynamic profiles should be used for billing or settlement for these three rate groups.

All SCE rate group load profiles are reported in Pacific Standard Time (PST), with hourly values recorded in kW.

 

2010 Static Load Profiles
Customer Class (Rate Group) Load Profile Id (text Files) Description Rate Schedules
Domestic DOM-S/M Domestic Single/Multiple DOMESTIC, D-CARE, D-CARE-APS, D-CARE-APS-E, DE, DE-APS, DE-APS-E, DE-FERA, DE-S, DE-FERA-APS, DE-FERA-APSE, DE-TOU-1, DE-TOU-2, D-APS, D-APS-E, D-FERA, D-FERA-APS, D-FERA-APS-E, D-PG-S, D-S, D-S-CARE, D-S-FERA, TOU-D-1, TOU-D-1-CARE, TOU-D-2, TOU-D-2-APS, TOU-D-2-CARE, TOU-D-T, TOU-D-T-APS, TOU-D-T-APSE, TOU-D-T-C-AE, TOU-D-T-CARE, TOU-D1-APS-E, TOU-D1-C-AE, TOU-D1-C-APS, TOU-D2-APS-E, TOU-D2-C-AE, TOU-D2-C-APS, TOU-DE-1-AE, TOU-DE-1-APS, TOU-DE-2-AE, TOU-DE-2-APS, TOU-DE-T, TOU-EV-1
Domestic DOM-MM Master-Metered DM, DM-CARE, DMS-1, DMS-2, DMS-3
LSMP GS-1 General Service, Non-demand Metered, Small Commercial GS-1, GS-1-APS, GS-1-APS-C, GS1-APS-E, GS-1-APS-E-C, GS-1-CARE, GS-1-CIF, GS-1-G-S, GS-1-SCE, TOU-EV-3, TOU-GS-1, TOU-GS-1-AE, TOU-GS-1-APS
LSMP TC-1 Traffic Control TC-1
LSMP GS-2 General Service, Demand Metered, Medium Commercial/Industrial GS-2, GS-2-A-C/GS1, GS-2-A/GS1, GS-2-AE/GS1, GS-2-AEC/GS1 GS-2-APS, GS-2-APS-C, GS-2-APS-E, GS2-APS-E-C, GS-2-C/GS1, GS-2-CARE, GS-2-S, GS-2-S/GS1, GS-2-SCE, GS-2/GS1, GS2T-A, GS2T-A-APS, GS2T-A-APS-E, GS2T-B, GS2T-B-APS, GS2T-B-APS-E, GS2T-B-EDW, GS2T-B-S, GS2T-B/GS1, GS2T-R, GS2TA/GS1, GS2TB-AE/GS1, SEQUOIA, TOU-EV-4
LSMP TOU-GS General Service, Time-of-Use, Medium Commercial/Industrial TGS3-C-CPP, TGS3-CPP. TOU-GS3-A, TOU-GS3-A-S, TOU-GS3-AAES, TOU-GS3-B, TOU-GS3-B-C, TOU-GS3-B-S, TOU-GS3-BAES, TOU-GS3-R, TOU-GS3-SOP, TOU-GS3A-AE, TOU-GS3A-APS, TOU-GS3B-AE, TOU-GS3B-APS, TOU-GS3B-EDW
AG&P PA-1 Small Agriculture & Pumping PA-1, PA-1-I, PA-1-SCE
AG&P PA-2 Agriculture & Pumping, Demand Metered PA-2, PA-2-I, PA-2-S, PA-2-SCE
AG&P TOU-PA-5 Agriculture & Pumping, Time-of-Use TOU-PA-5, TOU-PA-5-I, TOU-PA-5-S
AG&P Ag-TOU Agriculture & Pumping, Time-of-Use TOU-P-S-1-AP, TOU-P-S-2-AP, TOU-PA-A, TOU-PA-B , TOU-PA-B-I, TOU-PA-B-S, TOU-PA-ICE, TOU-PA-ICE-I, TOU-PA-SOP-1, TOU-PA-SOP-2
 
NOTE: RATE SCHEDULE AND VOLTAGE (KV) LEVEL DETERMINE LARGE POWER LOAD PROFILE ID.
Large Power TOU8-SEC General Service, Time-of-Use,Large Power(>500 kW), Secondary Voltage
(Below 2 kv)
RTP-2, RTP-2-S, RTP-2-SGDR-T, TOU-8, TOU-8-B, TOU-8-B-AE-S, TOU-8-B-APS, TOU-8-B-APSE, TOU-8-B-S, TOU-8-CPP, TOU-8-R, TOU-8-S
Large Power TOU8-PRI General Service, Time-of-Use,Large Power (>500 kW), Primary Voltage
(2 kv - 50 kv)
RTP-2, RTP-2-S, RTP-2-SGDR-T, TOU-8, TOU-8-B, TOU-8-B-AE-S, TOU-8-B-APS, TOU-8-B-APSE, TOU-8-B-S, TOU-8-CPP, TOU-8-EDW, TOU-8-R, TOU-8-S
Large Power TOU8-SUB General Service, Time-of-Use,Large Power (>500 kW), Sub-Transmission Voltage
(Above 50 kv)
RTP-2, RTP-2-S, RTP-2-SGDR-T, TOU-8, TOU-8-B, TOU-8-B-AE-S, TOU-8-B-APS, TOU-8-B-APSE, TOU-8-B-S, TOU-8-CPP, TOU-8-EDW, TOU-8-R, TOU-8-S, MARCH-AFB
Street Lighting St-Ltng Street and Area Lighting AL-2-A, AL-2-B, DWL-A, DWL-B, DWL-C, LS-1, LS-2, LS-2-4, LS-2- B, LS-3, OL-1, OL-1-ALLNITE, LS-1-ALLNITE, LS-1-MIDNITE, LS-1-TAP

If you have any questions regarding SCE load profiling, please contact Cyrus Sorooshian at SCE.