Regulatory Information - SCE Load Profiles
2002 Static Load Profiles

The data files in this section are static load profiles for 2002. Each file is a rate group annual profile developed using a three-year average of historical rate group load profiles. These load profiles are based on the 1997-1999 class average load profiles for 11 separate groups. Refer to the methodology of creating static load profiles for a description of the estimation process.

On May 18, 1998, SCE began implementing dynamic load profiles in place of static profiles for residential (Domestic Single/Multiple), Small Commercial (GS-1), and medium commercial/industrial (GS-2) customers. As of that date, only dynamic profiles should be used for billing or settlement for these three rate groups.

All SCE rate group load profiles are reported in Pacific Standard Time (PST), with hourly values recorded in kW. Click here for details on the file format, and click here for instructions on reading and using the profiles.

Customer Class (Rate Group) Load Profile Id Description Rate Schedules
Domestic DOM-S/M Domestic Single/Multiple. D, D-CARE, DE, DS, TOU-D-1, TOU-D-2,TOU-EV-1, TOU-EV-2.
  DOM-MM Master-Metered DM, DMS-1, DMS-2, DMS-3.
LSMP GS-1 General Service,Non-demand Metered,Small Commercial GS-1, TOU-GS-1, TOU-EV-3.
  TC-1 Traffic Control TC-1
  GS-2 General Service,Demand Metered, Medium Commercial/Industrial GS-2, GS-2-RTP, RTP-2-GS, RTP-3-GS,TOU-EV-4.
  TOU-GS General Service,Time-of-Use, Medium Commercial/Industrial TOU-GS-2, TOU-GS-2-SOP.
AG&P PA-1 Small Agriculture & Pumping PA-1
  PA-2 Agriculture & Pumping,Demand Metered PA-2
  TOU-PA-5 Agriculture & Pumping, Time-of-Use TOU-PA-5.
  Ag-TOU Agriculture & Pumping,Time-of-Use PA-RTP, TOU-PA, TOU-PA-3, TOU-PA-4, TOU-PA-6, TOU-PA-7, TOU-PA-SOP, TOU-PA-SOP-I.
Large Power TOU8-SEC General Service,Time-of-Use,Large Power(>500 kW), Secondary Voltage (Below 2 kv) TOU-8-S, I-6-S, RTP-2-S, RTP-2-I-S, RTP-3-S, TOU-8-CR-1-S, TOU-8-RTP-S, TOU-8-SOP-S, TOU-SOP-I-S, TOU-8-SOP-RTP-S.
  TOU8-PRI General Service,Time-of-Use,Large Power(>500 kW),Primary Voltage (2 kv - 50 kv) TOU-8-P, I-6-P, RTP-2-P, RTP-2-I-P, RTP-3-P, TOU-8-CR-1-P, TOU-8-RTP-P, TOU-8-SOP-P, TOU-SOP-I-P, TOU-8-SOP-RTP-P.
  TOU8-SUB General Service,Time-of-Use,Large Power(>500 kW), Sub-Transmission Voltage (Above 50 kv) TOU-8-T, I-6-T, RTP-2-T, RTP-2-I-T, RTP-3-T, TOU-8-CR-1-T, TOU-8-RTP-T, TOU-8-SOP-T, TOU-SOP-I-T, TOU-8-SOP-RTP-T.
Street Lighting St-Ltng Street and Area Lighting AL-1, DWL, LS-1, LS-2, LS-3, OL-1.

If you have any questions regarding SCE load profiling, please contact Cyrus Sorooshian at SCE.